Description
-
Highlights
- Move to the forefront of mobile 3D imaging with CT-like image quality
- Extend your intraoperative imaging capabilities for 2D, 3D and multidisciplinary use
- Master your quality outcome with image-guided surgery and workflow wizards
- Reduce exposure significantly with benchmark dose settings and hardware improvements
-
Features and Benefits
- Latest CMOS flat-panel technology for CT-like image quality
- Pulsed monoblock generator with 25 kW power performance
- Full control of 4 motorized axes via the Position Control Center (joystick module) and touchscreen with variable isocenter
- More distinguishable anatomy in 3D reconstructions with ZIR (Ziehm Iterative Reconstruction)
- Different volume sizes for the ideal resolution with 320³ voxel or 512³ voxel
- Patented SmartScan technology for complete 3D information
- Open navigation interface Ziehm NaviPort for image-guided 3D navigation of leading navigation system providers
- Ziehm Usability Concept combining a unique and finely tuned set of hardware features with seamlessly integrated software functionalities
-
Image Quality
- Comprehensive dose concept for high image quality and minimized dose
- Automatic optimization of dose and image quality with advanved anatomical programs
- Dedicated functions to significantly reduce exposure in pediatric surgery4
- Beam Filtration for reduced skin entrance dose without compromising on image quality for all CMOSline systems
-
Technical Details
- Footprint: 0.8 m²
- Generator: 25 kW pulsed monoblock generator
- Flat-panel technology:
30 cm x 30 cm (a-Si)
31 cm x 31 cm (CMOS) - 3D volume size / voxel (a-Si):
16 cm x 16 cm x 16 cm; (320)³ voxel
optional: 10 cm x 10 cm x 10 cm; (320)³ voxel
optional: 19.8 cm x 19.6 cm x 18.0 cm; (320)³ voxel - 3D volume size / voxel (CMOS):
16 cm x 16 cm x 16 cm; (320)³ / (512)³ voxel
optional: 10 cm x 10 cm x 10 cm; (320)³ / (512)³ voxel
optional: 19.8 cm x 19.6 cm x 18.0 cm; (320)³ / (512)³ voxel - Detector resolution:
1.5k x 1.5k matrix (a-Si)
3k x 3k matrix (CMOS) - Shades of gray: 65,536
- 1 CMOSline represents a system configuration that is based on a Ziehm Imaging CMOS flat-panel detector.
2 This product/feature might not be commercially available in all countries. Due to regulatory reasons their future availability cannot be guaranteed. Please contact Ziehm Imaging for detailed information.
3 The technology Beam Filtration reduces dose exposure for all CMOSline systems in comparison to conventional filtration techniques (Status before September 2017). Data on File. Results may vary
4 Gosch D. et al. “Influence of grid and ODDC on radiation exposure and image quality using mobile C-arms – First results”, RöFo, 09/07